| Inorganic Structure Prediction |


This chapter explains...
For information about
See
More on DLS
DLS-76 documentation available over the web or via conventional mail request (see below)
Discover
Cerius2 Discover manual
40
Accessing the tools
To access the card in the C2·DLS module, click the deck selector in the main control panel and choose STRUCTURE SOLVE from the list that appears. Then click the title of the DLS card to bring it to the fore. The deck of cards menu area should now look like this:

This chapter explains how to use the Cerius2 DLS user interface and does not discuss DLS-76 in great detail.
A note about the scope of this documentation

Cerius2 DLS is complemented by the Cerius2 Diffraction-Crystal module for simulation of powder diffraction patterns and Cerius2 Rietveld for further refinement of structures using powder diffraction data.

Once the user has sketched an initial crystal, using the model building tools available in the Cerius2 Visualizer and Cerius2 Crystal Builder, a set of default distance and angle constraints can be automatically applied, and then edited manually if required. Running DLS-76 is then as simple as pressing a button -- the results are fed directly back to the screen in the form of the refined structure.
In generating a list of bonds, the following rules are applied:
DLS is run from the DLS Controls control panel, accessible by clicking Controls on the DLS menu card. It may be run either INTERACTIVELY, or in the BACKGROUND (set in the Mode of running DLS popup). For most work, it is envisaged that interactive operation will be fast enough. The user should specify a seed filename in the Current filename seed entry box, which will be used for all files generated by the run. The default seed is "dls".
DLS constraints
DLS-76 requires a large number of constraints to be specified in order to refine the structure. These constraints are normally generated automatically. If insufficient constraints are specified, the refinement will fail and Cerius2 will issue a warning message. A special case occurs when an atom does not appear in the list of constraints. In this case the atom will have its fractional coordinates fixed by default, and will not interfere with the refinement of the remainder of the crystal.
The distance constraints and weightings that Cerius2 assigns to each bond are taken from the constraint list in the DLS Set-up Atom Pair Constraints control panel (accessible by selecting Constraints
Set-up Atom Pairs). There is a default set in the list when Cerius2 is run -- others may be loaded from file or put in by hand and the existing list may be edited.
If Cerius2 finds a 1-3 distance in the model which is not included in the constraint list, then the distance will not be constrained.
If Cerius2 finds a 1-2 distance in the model but not in the constraint list, then Cerius2 will give a warning and, if Use Slater radii is set to YES, will substitute a distance equal to the sum of the elemental Slater radii.
The distance constraint list can be easily edited to add or remove bonds, change distances and angles and change the bond weight.
The controls on the dialog box require the following input (all input to text boxes is in "free format"):
Add bond constraint: atom1 atom2 distance weight Add 1-3 constraint: atom1 atom2 atom3 distance weight Add angle constraint: atom1 atom2 atom3 angle weight Change value of con- List number new
straint: value Change weight of List number new
constraint: weight Remove constraint List number
from list:
Cerius2 has a default constraint file containing constraints for some common atom pairs which are initially loaded into Cerius2. Once you have a customized constraint file you can load that instead.
Fixed Atoms. Cerius2 automatically fixes any non-bonded atoms in the model.Atoms are added to the fixed atom list by selecting the atom(s) from the model and clicking the Add selected atoms to list button. It may be necessary to fix one atom to get DLS to converge. Be careful constraining special position atoms -- DLS does not like this!
The Edit Atom Pair Table control panel lets you edit individual atom pair constraints. The whole atom pair table can be listed and also sorted by NUMBER or ELEMENT for clarity. Selecting two atoms on the screen and clicking the Show constraint for selected atoms button displays the current constraint, if any, for the atom pair. The current constraint can then be modified or a fresh constraint added.
For more information on the controls within the panels and subpanels, please refer to the online help text. To access the help text, place your mouse cursor over a control or panel and press the right mouse button.
DLS Controls control panel
This panel allows you to set up a control file for a DLS run from the current model structure, to run the control file, and to recover results from a run.
Constraints control panel
This panel allows you to list and modify the table of atom pair constraints for the DLS run.
Set-up Atom Pairs from the DLS menu card.
This control pane allows you to load from a file, or save to a file, the DLS atom pair constraints.
Load/Save Atom Pairs from the DLS menu card.
Constraints control panel
This control panel allows you to set up and edit the list of fixed atoms for the DLS run.
Fixed Atoms from the DLS menu card.
This control panel allows you to specify constraints on the unit cell parameters for a DLS run.
Unit Cell Parameters from the DLS menu card.
This control panel allows the user to modify the refinement options for the DLS run.
This control panel allows the user to list and edit the table of current atom pair distance constraints for a DLS run.
Edit Atom Pair Table from the DLS menu card.