Inorganic Structure Prediction




3       DLS menu card

This chapter discusses the DLS menu card found in the Cerius2 Structure Solve deck of cards.


Introduction

The Cerius2 DLS (Distance Least Squares) is an easy to use interface to the DLS-76 program of Baerlocher, Hepp and Meier for geometric refinement of crystal structures. DLS-76 is used extensively to help solve crystal structures of technologically important materials such as zeolites and other microporous solids used in catalysis and separations technology.

This chapter explains...

A note about the scope of this documentation 34

Overview 35

Design of the Cerius2 DLS user interface 35

DLS controls: initializing and running 36

DLS constraints 37

Unit cell parameters 39

Refinement options 39

Advanced features 39

DLS control panels

For information about See
More on DLS     DLS-76 documentation available over the web or via conventional mail request (see below)  
Discover     Cerius2 Discover manual  
40

Accessing the tools

To access the card in the C2·DLS module, click the deck selector in the main control panel and choose STRUCTURE SOLVE from the list that appears. Then click the title of the DLS card to bring it to the fore. The deck of cards menu area should now look like this:


A note about the scope of this documentation

This chapter explains how to use the Cerius2 DLS user interface and does not discuss DLS-76 in great detail.

To get the most from the DLS interface, therefore, you are strongly advised to read the full DLS-76 documentation. You can do this by pointing your browser to:

http://kristall.erdw.ethz.ch/software/dls76manual.html

The html version of the documentation does not contain graphics or formulas. Hard copies may be obtained from the following addresses:

S.L. Lawton
Research Department
Mobil Research and Development Corporation
Paulsboro
NJ 08066
USA

and in Australia, from:

Dr. E.W. Radoslovich
CSIRO
Division of Soils
Glen OSmond
South Australia 5064


Overview

Trial crystals can be set up and manipulated on screen using the crystal building, symmetry, editing and visualization capabilities of the Cerius2 Crystal Builder. DLS-76 refinement can then be applied to the on-screen model at the touch of a button. Refinement optimizes interatomic distances and the crystal unit cell parameters. Refined crystals are read directly back into Cerius2 for redisplay and analysis of results.

Cerius2 DLS is complemented by the Cerius2 Diffraction-Crystal module for simulation of powder diffraction patterns and Cerius2 Rietveld for further refinement of structures using powder diffraction data.


Design of the Cerius2 DLS user interface

The DLS user interface is designed to make it quick and easy to set up refinements of crystal structures using the DLS-76 program.

Once the user has sketched an initial crystal, using the model building tools available in the Cerius2 Visualizer and Cerius2 Crystal Builder, a set of default distance and angle constraints can be automatically applied, and then edited manually if required. Running DLS-76 is then as simple as pressing a button -- the results are fed directly back to the screen in the form of the refined structure.

DLS controls: initializing and running

How to set up DLS

On first entering DLS, it is necessary to initialize it for the current crystal model. This performs two functions:

To initialize, click Set up atom pair table in the DLS Controls control panel, accessible by clicking Controls on the DLS menu card. This will need to be done every time constraints are altered by the user. Once this has been done, DLS is ready to be run.

In generating a list of bonds, the following rules are applied:

Running DLS-76

DLS is run from the DLS Controls control panel, accessible by clicking Controls on the DLS menu card. It may be run either INTERACTIVELY, or in the BACKGROUND (set in the Mode of running DLS popup). For most work, it is envisaged that interactive operation will be fast enough. The user should specify a seed filename in the Current filename seed entry box, which will be used for all files generated by the run. The default seed is "dls".

The Write DLS command file option is provided for your convenience. In order to run DLS, you need only click Run DLS using current parameters.

The results of an interactive run are automatically recovered and displayed on the screen. If running in the background, it is necessary to use the Recover results of DLS run button to recover the results manually.

Further control may be exercised over the run by using the Refinement Options control panel (see "Refinement options" on page 39).

DLS constraints

DLS-76 requires a large number of constraints to be specified in order to refine the structure. These constraints are normally generated automatically. If insufficient constraints are specified, the refinement will fail and Cerius2 will issue a warning message. A special case occurs when an atom does not appear in the list of constraints. In this case the atom will have its fractional coordinates fixed by default, and will not interfere with the refinement of the remainder of the crystal.

Atom pair constraints

The distance constraints and weightings that Cerius2 assigns to each bond are taken from the constraint list in the DLS Set-up Atom Pair Constraints control panel (accessible by selecting Constraints Set-up Atom Pairs). There is a default set in the list when Cerius2 is run -- others may be loaded from file or put in by hand and the existing list may be edited.

There are three different constraint types (see the List of constraints in the DLS Set-up Atom Pair control panel).

BOND: constraints between directly bonded atoms.

ANGLE: constraints for indirectly bonded atoms.

13DIST: constraints for indirectly bonded atoms.

If atoms 1 and 3 are both bonded to atom 2 then the 1-3 distance constraint can either be specified directly (13DIST) or via the 1-2-3 bond angle (ANGLE). If both specifications are in the constraint list then the Angle/distance precedence popup will dictate which is used.

If Cerius2 finds a 1-3 distance in the model which is not included in the constraint list, then the distance will not be constrained.

If Cerius2 finds a 1-2 distance in the model but not in the constraint list, then Cerius2 will give a warning and, if Use Slater radii is set to YES, will substitute a distance equal to the sum of the elemental Slater radii.

The distance constraint list can be easily edited to add or remove bonds, change distances and angles and change the bond weight.

The controls on the dialog box require the following input (all input to text boxes is in "free format"):


Add bond constraint: 	atom1	atom2	distance	weight


Add 1-3 constraint: 	atom1	atom2	atom3	distance 		weight


Add angle constraint: 	atom1	atom2	atom3	angle		weight


Change value of con-	List number	new
straint: value
Change weight of List number new
constraint: weight
Remove constraint List number
from list:

Load/save atom pair constraints

The complete constraint table can be saved as a constraint file and further constraints can be loaded from the Constraints Load/Save Atom Pairs control panel, accessible from the Load/Save... button on the DLS Set-up Atom Pair Constraints control panel.

Cerius2 has a default constraint file containing constraints for some common atom pairs which are initially loaded into Cerius2. Once you have a customized constraint file you can load that instead.

Fixed atom constraints

Cerius2 lets you fix the x, y and z coordinates of any atom in the model by entering it into the fixed atom list in the DLS Fixed Atom Constraints control panel, accessible from Constraints Fixed Atoms. Cerius2 automatically fixes any non-bonded atoms in the model.

Atoms are added to the fixed atom list by selecting the atom(s) from the model and clicking the Add selected atoms to list button. It may be necessary to fix one atom to get DLS to converge. Be careful constraining special position atoms -- DLS does not like this!

Unit cell parameters

The Constraints Unit Cell Parameters control panel lets you select which of the cell parameters are to be refined in the DLS run. The space group symmetry is taken into account, for example if a is set to vary in the cubic space-group, then b and c will automatically be set to vary.

Refinement options

The Refinement Options control panel, accessible by clicking Refinement Options on the DLS menu card, gives you control over various DLS parameters and options such as Refinement method (NEWTON-RAPHSON or GAUSS-NEWTON); Maximum number of cycles; Apply convergence test; Convergence factor; FIXED or VARIABLE damping; and Cell and Coordinate damping factors.

Advanced features

The tools under Advanced Features allow a degree of control over DLS which will not usually be needed by the casual user.

The Edit Atom Pair Table control panel lets you edit individual atom pair constraints. The whole atom pair table can be listed and also sorted by NUMBER or ELEMENT for clarity. Selecting two atoms on the screen and clicking the Show constraint for selected atoms button displays the current constraint, if any, for the atom pair. The current constraint can then be modified or a fresh constraint added.

DLS control panels

The functionality in DLS is organized into seven main control panels. For reference, each of which is briefly described in the following paragraphs.

For more information on the controls within the panels and subpanels, please refer to the online help text. To access the help text, place your mouse cursor over a control or panel and press the right mouse button.

DLS Controls control panel

This panel allows you to set up a control file for a DLS run from the current model structure, to run the control file, and to recover results from a run.

To open this panel, click Controls on the DLS menu card.

DLS Set-up Atom Pair
Constraints control panel

This panel allows you to list and modify the table of atom pair constraints for the DLS run.

To open this panel, select Constraints Set-up Atom Pairs from the DLS menu card.

DLS Load/Save Atom Pair Constraints control panel

This control pane allows you to load from a file, or save to a file, the DLS atom pair constraints.

To open this panel, select Constraints Load/Save Atom Pairs from the DLS menu card.

DLS Fixed Atom
Constraints control panel

This control panel allows you to set up and edit the list of fixed atoms for the DLS run.

To open this panel, select Constraints Fixed Atoms from the DLS menu card.

DLS Unit Cell Constraints control panel

This control panel allows you to specify constraints on the unit cell parameters for a DLS run.

To open this panel, select Constraints Unit Cell Parameters from the DLS menu card.

DLS Refinement Options control panel

This control panel allows the user to modify the refinement options for the DLS run.

To open this panel, click Refinement Options on the DLS menu card.

DLS Edit Atom Pair Table control panel

This control panel allows the user to list and edit the table of current atom pair distance constraints for a DLS run.

To open this panel, select Advanced Features Edit Atom Pair Table from the DLS menu card.




Last updated November 25, 1998 at 03:59PM PST.